Pneumatic solenoid valves may encounter the following common problems in operation and their solutions :
Youdaoplaceholder0 Pneumatic solenoid valve is not WORKING properly :
Youdaoplaceholder0 Power supply problem : Check if the power cord is properly connected, if the voltage is stable, and rule out the possibility of power failure.
Youdaoplaceholder0 Circuit connection problem : Check if the circuit connection of the pneumatic solenoid valve is loose, short-circuited or disconnected, and make sure the circuit connection is correct.
Youdaoplaceholder0 Air supply issues : Check if the air supply pipeline is normal and if the air pressure meets the usage requirements of the pneumatic solenoid valve 1.
Youdaoplaceholder0 Air leakage of pneumatic solenoid valve :
Youdaoplaceholder0 Seal problem : Check for wear or aging of the seals of the pneumatic solenoid valve, such as O-rings and gaskets, and replace them in time.
Youdaoplaceholder0 Connection fastening problem : Check whether the connection threads and other components of the pneumatic solenoid valve are fastened tightly and tighten them in time.
Youdaoplaceholder0 Cleaning issues : Regularly clean the pneumatic solenoid valve to remove accumulated dust and impurities in the valve body and keep the valve body unobstructed 12.
Youdaoplaceholder0 Pneumatic solenoid valve stuck or not sensitive :
Youdaoplaceholder0 Gas source quality issue : Check the gas source for any dirt such as oil or water, and purify it with a filter.
Youdaoplaceholder0 Piston and spool problems : Check the piston and spool in the pneumatic solenoid valve for damage, wear or jamming, and replace or repair them in time.
Youdaoplaceholder0 Lubrication issues : Regularly add lubricating oil to the pneumatic solenoid valve according to its usage requirements to ensure smooth movement of the parts 12.
Youdaoplaceholder0 Pneumatic solenoid valve OVERHEATING :
Youdaoplaceholder0 Ambient temperature : Check whether the temperature of the working environment where the pneumatic solenoid valve is located exceeds its rated operating temperature range and take cooling measures.
Youdaoplaceholder0 Air supply pressure : Check if the air pressure in the air supply pipeline exceeds the maximum pressure that the pneumatic solenoid valve can withstand. Reduce the air supply pressure.
Youdaoplaceholder0 Heat dissipation measures : Check if the heat dissipation measures of the pneumatic solenoid valve are in place, install heat sinks, etc. Youdaoplaceholder2 12.
Youdaoplaceholder0 PNEUMATIC solenoid valve TOO NOISY :
Youdaoplaceholder0 Supply air pressure : Check if the required supply air pressure of the pneumatic solenoid valve is lower than the rated pressure and increase the supply air pressure.
Youdaoplaceholder0 Seal condition : Check if the seals of the pneumatic solenoid valve are in good condition and replace any aged seals in time.